Catracure PMMA Posterior Chamber IOL PS 5525

REQUEST CALLBACK

Catracure  PMMA Posterior Chamber IOL PS 5525
Ask for Price

Thanks for Contacting Us.

Product Price :Get Latest Price

Catracure PS5525 IOLs are made up of high quality PMMA lens. It is placed behind the iris in the capsule. Implantation inside the capsular bag (first choice) or fix into the sulcus if the capsular bag is damaged. It is the widely used IOL for cataract surgery.

Product features:
  • Larger optic diameter.
  • Improved the PCO protection efficiency of the square edge.
  • Increased stability.
  • Clear vision.

Technical Specifications:

Model

PS 5525

Optic Diameter

5.50mm

Overall Diameter

12.50 mm

Optic Design

Spherical Bi-convex

Available Powers

-5.0 D to +35.0 D (+10.0 D to +35.0 D in 0.5 D steps, -5.0 D to +9.0 D +31.0 to +35.0 D in 1.0 D Steps)

Haptic Design

"C" design with Step Vault

Dialing Holes

Nil

Suggested A. constant

118.4

Yes! I am interested

Catracure PMMA Posterior Chamber IOL PS6025

REQUEST CALLBACK

Catracure PMMA Posterior Chamber IOL PS6025
Ask for Price

Thanks for Contacting Us.

Product Price :Get Latest Price

Catracure PS6025 IOLs are made up of high quality PMMA lens. It is placed behind the iris in the capsule. Implantation inside the capsular bag (first choice) or fix into the sulcus if the capsular bag is damaged. It is the widely used IOL for cataract surgery.

Product features:
  • Larger optic diameter.
  • Improved the PCO protection efficiency of the square edge.
  • Increased stability.
  • Clear vision.

Technical Specifications:

Model

PS 6025

Optic Diameter

6.00 mm

Overall Diameter

12.50 mm

Optic Design

Spherical Bi-convex

Available Powers

-5.0 D to +35.0 D (+10.0 D to +35.0 D in 0.5 D steps, -5.0 D to +9.0 D +31.0 to +35.0 D in 1.0 D Steps)

Haptic Design

"C" design with Step Vault

Dialing Holes

Nil

Suggested A. constant

118.4

Yes! I am interested

Catracure Scleral Fixation IOL PS 6535

REQUEST CALLBACK

Catracure Scleral Fixation IOL PS 6535
Ask for Price

Thanks for Contacting Us.

Product Price :Get Latest Price

Catracure PS6535 IOLs are made up of high quality PMMA lens. It is placed behind the iris in the capsule. Implantation inside the capsular bag (first choice) or fix into the sulcus if the capsular bag is damaged. It is the widely used IOL for cataract surgery.

Product features:
  • Larger optic diameter.
  • Improved the PCO protection efficiency of the square edge.
  • Increased stability.
  • Clear vision.

Technical Specifications:

Model

PS 6535

Optic Diameter

6.50mm

Overall Diameter

13.50 mm

Optic Design

Spherical Bi-convex

Available Powers

-5.0 D to +35.0 D (+10.0 D to +35.0 D in 0.5 D steps, -5.0 D to +9.0 D +31.0 to +35.0 D in 1.0 D Steps)

Haptic Design

"C" design with Step Vault

Dialing Holes

Nil

Suggested A. constant

118.4

Yes! I am interested

Catracure Anterior Chamber IOL AC6025

REQUEST CALLBACK

Catracure Anterior Chamber IOL AC6025
Ask for Price

Thanks for Contacting Us.

Product Price :Get Latest Price

Catracure Anterior chamber AC6025 IOL is fixed with the support of iris. It is used as backup lens primarily when there is damage to the Posterior Chamber. Anterior Chamber IOL is also used in refractive surgery – implanting a lens in phakic eye to correct the refractive power.

Features:

  • Improved the PCO protection efficiency of the square edge
  • Increased stability.
  • Clear vision.
  • Smooth lens surface
  • Available in different powers
  • Step-vaulted haptic design.
  • YAG Laser Compatible.
Technical Specifications:

Model

AC 6025

Optic Diameter

6.00mm

Overall Diameter

12.50 mm

Optic Design

Spherical Bi-convex

Available Powers

-5.0 D to +35.0 D (+10.0 D to +35.0 D in 0.5 D steps, -5.0 D to +9.0 D +31.0 to +35.0 D in 1.0 D Steps)

Haptic Design

"S" design with Step Vault

Dialing Holes

Nil

Suggested A. constant

115.3

Yes! I am interested

Catracure Iris Fixation Phakic IOL PS4272

REQUEST CALLBACK

Catracure Iris Fixation Phakic IOL PS4272
Ask for Price

Thanks for Contacting Us.

Product Price :Get Latest Price

Catracure Iris Fixation Phakic IOL PS4272 IOLs are meant for the correction of refractive errors, providing patients with high quality vision. These are inserted either on top of the iris or in between the iris and the natural lens. They are used to treat refractive error without removing cornea tissue or the lens.

Technical Specifications:

Model

PS 4272

Optic Diameter

4.25 mm

Overall Diameter

7.25 mm

Optic Design

Spherical Bi-convex

Haptic Design

"S" design with Step Vault

Dialing Holes

Nil

Suggested A. constant

115.3

Yes! I am interested

Catracure Iris Fixation Phakic IOL PS5580

REQUEST CALLBACK

Catracure Iris Fixation Phakic IOL PS5580
Ask for Price

Thanks for Contacting Us.

Product Price :Get Latest Price

Catracure Iris Fixation Phakic IOL PS5580 IOLs are meant for the correction of refractive errors, providing patients with high quality vision. These are inserted either on top of the iris or in between the iris and the natural lens. They are used to treat refractive error without removing cornea tissue or the lens.

Features:

 

  • Improved the PCO protection efficiency of the square edge
  • Increased stability.
  • Clear vision.
  • Smooth lens surface
  • Available in different powers
  • Step-vaulted haptic design.
  • YAG Laser Compatible.
Technical Specifications:

Model

PS 5580

Optic Diameter

5.50mm

Overall Diameter

8.00 mm

Optic Design

Spherical Bi-convex

Haptic Design

"S" design with Step Vault

Dialing Holes

Nil

Suggested A. constant

115.3

Yes! I am interested

Catracure Iris Fixation Phakic IOL PS5085

REQUEST CALLBACK

Catracure Iris Fixation Phakic IOL PS5085
Ask for Price

Thanks for Contacting Us.

Product Price :Get Latest Price

Catracure Iris Fixation Phakic IOL PS5085 IOLs are meant for the correction of refractive errors, providing patients with high quality vision. These are inserted either on top of the iris or in between the iris and the natural lens. They are used to treat refractive error without removing cornea tissue or the lens.

Technical Specifications:

Model

PS 5085

Optic Diameter

5.00 mm

Overall Diameter

8.50 mm

Optic Design

Spherical Bi-convex

Haptic Design

"S" design with Step Vault

Dialing Holes

Nil

Suggested A. constant

115.3

Yes! I am interested

 
X


Explore More Products

Contact via E-mail
Contact via SMS
Global Ophthalmic Private Limited
Kamban Selvaraj (Marketing Manager)
Plot No. 3, First Main Road, Sri Ramsamaji Nagar Extension, Vellanoor , Bharathi Nagar,
Chennai - 600062, Tamil Nadu, India
Call Us: 
Call Response Rate: 70%
Share Us :
F G T L



Home  |   Profile   |  Our Products  |  Site Map  |   Contact Us

© Global Ophthalmic Private Limited. All Rights Reserved (Terms of Use)
Developed and Managed by IndiaMART InterMESH Limited

Global Ophthalmic Private Limited