ANTERIOR CHAMBER INTRAOCULAR LENSES

Anterior Chamber IOL is also used in refractive surgery – implanting a lens in phakic eye to correct the refractive power

Glowvision

REQUEST CALLBACK

Glowvision
Ask for Price

Thanks for Contacting Us.

Product Price :Get Latest Price

Product Details:
TypeAnterior Chamber IOL
MaterialPMMA
Usage/ApplicationEye Diseases/ Cataract Surgery
Optic DesignSpherical Bi-convex
Lens TypePmma Intraocular Lenses
Overall Length12.50 mm
Lens ModelAC 6025
Haptic Design"S" design with Step Vault
Optic Diameter6.00mm
Drilling HolesNil
Available Powers+10.0 D to +35.0 D in 0.5 D steps; -5.0 D to +9.0 D & +31.0 to +35.0 D in 1.0 D Steps
SterilizationYes
Suggested A. constant115.3

GLOWvision Anterior chamber IOL is fixed with the support of iris. It is used as backup lens primarily when there is damage to the Posterior Chamber. Anterior Chamber IOL is also used in refractive surgery – implanting a lens in phakic eye to correct the refractive power.

Features:

  • Improved the PCO protection efficiency of the square edge.
  • Increased stability.
  • Clear vision.
  • Smooth lens surface.
  • Available in different powers.
  • Step-vaulted haptic design.
  • YAG Laser Compatible.
Yes! I am interested

Optiol

REQUEST CALLBACK

Optiol
Ask for Price

Thanks for Contacting Us.

Product Price :Get Latest Price

Product Details:
TypeAnterior Chamber Intraocular Lenses
MaterialPMMA
Usage/ApplicationEye Diseases/ Cataract Surgery
Optic DesignSpherical Bi-convex
Lens TypePmma Intraocular Lenses
Overall Length12.50 mm
Lens ModelOAC 6025
Haptic Design"S" design with Step Vault
Optic Diameter6.00mm
Drilling HolesNil
Available Powers+10.0 D to +35.0 D in 0.5 D steps; -5.0 D to +9.0 D & +31.0 to +35.0 D in 1.0 D Steps
SterilizationYes
Suggested A. constant115.3

OPTIOL Anterior chamber IOL is fixed with the support of iris. It is used as backup lens primarily when there is damage to the Posterior Chamber. Anterior Chamber IOL is also used in refractive surgery – implanting a lens in phakic eye to correct the refractive power.

Features:

  • Improved the PCO protection efficiency of the square edge.
  • Increased stability.
  • Clear vision.
  • Smooth lens surface.
  • Available in different powers.
  • Step-vaulted haptic design.
  • YAG Laser Compatible.
Yes! I am interested

Catracure

REQUEST CALLBACK

Catracure
Ask for Price

Thanks for Contacting Us.

Product Price :Get Latest Price

Product Details:
TypeAnterior Chamber IOL
MaterialPMMA
Usage/ApplicationEye Diseases/ Cataract Surgery
Optic DesignSpherical Bi-convex
Lens TypePmma Intraocular Lenses
Overall Length12.50 mm
Lens ModelCAC 6025
Haptic Design"S" design with Step Vault
Optic Diameter6.00 mm
Drilling HolesNil
Available Powers+10.0 D to +35.0 D in 0.5 D steps; -5.0 D to +9.0 D & +31.0 to +35.0 D in 1.0 D Steps
SterilizationYes
Suggested A. constant115.3

CATRACURE Anterior chamber IOL is fixed with the support of iris. It is used as backup lens primarily when there is damage to the Posterior Chamber. Anterior Chamber IOL is also used in refractive surgery – implanting a lens in phakic eye to correct the refractive power.

Features:

  • Improved the PCO protection efficiency of the square edge.
  • Increased stability.
  • Clear vision.
  • Smooth lens surface.
  • Available in different powers.
  • Step-vaulted haptic design.
  • YAG Laser Compatible.
Yes! I am interested

Iovue

REQUEST CALLBACK

Iovue
Ask for Price

Thanks for Contacting Us.

Product Price :Get Latest Price

Product Details:
TypeAnterior Chamber Intraocular Lenses
MaterialPMMA
Usage/ApplicationEye Diseases/ Cataract Surgery
Optic DesignSpherical Bi-convex
Lens TypePmma Intraocular Lenses
Overall Length12.50 mm
Lens ModelIAC 6025
Haptic Design"S" design with Step Vault
Optic Diameter6.00 mm
Drilling HolesNil
Available Powers+10.0 D to +35.0 D in 0.5 D steps,-5.0 D to +9.0 D & +31.0 to +35.0 D in 1.0 D Steps
SterilizationYes
Suggested A. constant115.3

IOVUE Anterior chamber IOL is fixed with the support of iris. It is used as backup lens primarily when there is damage to the Posterior Chamber. Anterior Chamber IOL is also used in refractive surgery – implanting a lens in phakic eye to correct the refractive power.

Features:

  • Improved the PCO protection efficiency of the square edge.
  • Increased stability.
  • Clear vision.
  • Smooth lens surface.
  • Available in different powers.
  • Step-vaulted haptic design.
  • YAG Laser Compatible.
Yes! I am interested

 
X


Explore More Products

Contact via E-mail
Contact via SMS
Global Ophthalmic Private Limited
Kamban Selvaraj (Marketing Manager)
Plot No. 3, First Main Road, Sri Ramsamaji Nagar Extension, Vellanoor , Bharathi Nagar,
Chennai - 600062, Tamil Nadu, India
Call Us: 
Call Response Rate: 91%
Share Us :
F G T L



Home  |   Profile   |  Our Products  |  Site Map  |   Contact Us

© Global Ophthalmic Private Limited. All Rights Reserved (Terms of Use)
Developed and Managed by IndiaMART InterMESH Limited

Global Ophthalmic Private Limited