Send Email
Send SMS
Search
Global Ophthalmic Private Limited
Global Ophthalmic Private Limited


HYDROPHILIC ACRYLIC FOLDABLE IOLs

Offering you a complete choice of products which include optiol fold, hemafold, iovue, cfrance fold, flexiol ao and asprolenz.

OPTIOL FOLD

REQUEST CALLBACK

OPTIOL FOLD
  • OPTIOL FOLD
  • OPTIOL FOLD
Ask for Price

Thanks for Contacting Us.

Product Price :Get Latest Price

Product Details:
Minimum Order Quantity100 Piece
MaterialHydrophilic Foldable Acrylate
Usage/ApplicationEye Diseases/ Cataract Surgery
Optic DesignBiconvex
Lens TypeHydrophilic Acrylic Foldable Intraocular Lenses
Model Name/NumberOFS 6025, OFS 6025D
Optic Size6.00 mm
Estimated AC Depth4.96 mm
SterilizationSTEAM
Overall Length12.50 mm
Refractive Index1.46 @ 20 Degree C
Pco Protection360 Degree Step Square Edge on posterior Side
Haptic Design0 Degree Pre-vaulted
Available Powers+10.0 D to +35.0 D in 0.5 D steps, -5.0 D to +9.0 D & +31.0 to +35.0 D in 1.0 D Steps
Estimated A. constant118.0

We are providing our clients with a wide assortment of OPTIOL FOLD Hydrophilic Acrylic Foldable IOLs with enriched industrial experience and knowledge. Designed with precision, the offered lens is designed using quality-proven violet blue light filtering material with the aid of sophisticated technology in synchronization with set industry standards. In addition to this, the provided lens undergoes various tests by our quality controllers, in order to ensure its flawless nature.

Features:

  • Ultra-Pure Hydrophilic Acrylic Material with adequate UV blocking.
  • 26% Water Content.
  • 360° Square edge design provides uninterrupted contact at the haptic-optic junction to limit LEC's migration.
  • Smooth lens surface reduces bacterial adhesion, inflammatory cell response and haptics for ease of unfolding.
  • Pre-vaulted design – continuous posterior surface contact with the capsular bag to prevent PCO.
  • The advanced IOL design – Stable and Perfect centration and ultimate stability in the capsular bag.
  • Optics are YAG Laser Compatible
  • Steam sterilization does away with the hazards of ETO residue.
Yes! I am interested

HEMAFOLD

REQUEST CALLBACK

HEMAFOLD
  • HEMAFOLD
  • HEMAFOLD
  • HEMAFOLD
  • +1 HEMAFOLD
Ask for Price

Thanks for Contacting Us.

Product Price :Get Latest Price

Product Details:
Minimum Order Quantity100 Piece
MaterialHydrophilic Foldable Acrylate
Usage/ApplicationEye Diseases/ Cataract Surgery
Model Name/NumberFS 5725D,FS 6025,FS 6025D,FS 6030,FS 6005
Estimated AC Depth4.96 mm
SterilizationSTEAM
Refractive Index1.46 @ 20 Degree C
PCO Protection360 Degree Step Square Edge on posterior Side
Optic DesignBiconvex

With enriched industrial experience and knowledge, we are providing our clients with a wide assortment of Hema Fold  Hydrophilic Acrylic Foldable IOL. Designed with utmost precision, the offered lens is designed using quality-proven violet blue light filtering material with the aid of sophisticated technology in synchronization with set industry standards. In addition to this, the provided lens undergoes various tests by our quality controllers, in order to ensure its flawless nature.

Features:

  • Clear Hydrophilic
  • 26% Water Content
  • 360° Advanced Square edge


Other Details:

  • Ultra Pure Hydrophilic acrylic Material with adequate UV blocking
  • 360° Square edge design provides uninterrupted contact at the haptic-optic junction to limit LEE's migration
  • Smooth lens surface reduces bacterial adhesion, inflammatory cell response and haptics for ease of unfolding
  • Pre-vaulted design – continuous posterior surface contact with the capsular bag to prevent PCO
  • The advanced IOL design – Stable and Perfect centration and ultimate stability in the capsular bag
  • Optics are YAG Laser Compatible
  • Steam sterilization does away with the hazards of ETO residue.
Yes! I am interested

Iovue

REQUEST CALLBACK

Iovue
  • Iovue
  • Iovue
Ask for Price

Thanks for Contacting Us.

Product Price :Get Latest Price

Product Details:
Minimum Order Quantity100 Piece
MaterialHydrophilic Foldable Acrylate
Usage/ApplicationEye Diseases/ Cataract Surgery
Optic DesignBiconvex
Lens TypeHydrophilic Acrylic Foldable Intraocular Lenses
Model Name/NumberIFS 6025,IFS 6025D
Estimated AC Depth4.96 mm
Optic Size6.00 mm
SterilizationSTEAM
Overall Length12.50 mm
Pco Protection360 Degree Step Square Edge on posterior Side
Haptic Design0 Degree Pre-vaulted
Available Powers+10.0 D to +35.0 D in 0.5 D steps,-5.0 D to +9.0 D & +31.0 to +35.0 D in 1.0 D Steps
Estimated AC. Depth4.96 mm

We are providing our clients with a wide assortment of EUROFOLD Hydrophilic Acrylic Foldable IOL with enriched industrial experience and knowledge. Designed with utmost precision, the offered lens is designed using quality-proven violet blue light filtering material with the aid of sophisticated technology in synchronization with set industry standards. In addition to this, the provided lens undergoes various tests by our quality controllers, in order to ensure its flawless nature.

Features:

  • Ultra-Pure Hydrophilic Acrylic Material with adequate UV blocking.
  • 26% Water Content.
  • 360° Square edge design provides uninterrupted contact at the haptic-optic junction to limit LEE's migration.
  • Smooth lens surface reduces bacterial adhesion, inflammatory cell response and haptics for ease of unfolding.
  • Pre-vaulted design – continuous posterior surface contact with the capsular bag to prevent PCO.
  • The advanced IOL design – Stable and Perfect centration and ultimate stability in the capsular bag.
  • Optics are YAG Laser Compatible.
  • Steam sterilization does away with the hazards of ETO residue.
Yes! I am interested

CFRANCE FOLD

REQUEST CALLBACK

CFRANCE FOLD
Ask for Price

Thanks for Contacting Us.

Product Price :Get Latest Price

Product Details:
Minimum Order Quantity100 Piece
TypeAspheric IOLs
MaterialHydrophilic Foldable Acrylate
Usage/ApplicationEye Diseases/ Cataract Surgery
Optic DesignBiconvex
Lens TypeHydrophilic Acrylic Foldable Intraocular Lenses
Model Name/NumberFS 6025D
Optic Size6.00 mm
Estimated AC Depth4.96 mm
SterilizationSTEAM
Overall Length12.50 mm
Pco Protection360 Degree Step Square Edge on posterior Side
Available Powers+10.0 D to +35.0 D in 0.5 D steps

We are providing our clients with a wide assortment of CFRANCE FOLD Hydrophilic Acrylic Foldable IOLs with enriched industrial experience and knowledge. Designed with precision, the offered lens is designed using quality-proven violet blue light filtering material with the aid of sophisticated technology in synchronization with set industry standards. In addition to this, the provided lens undergoes various tests by our quality controllers, in order to ensure its flawless nature.

Features:

  • Ultra-Pure Hydrophilic Acrylic Material with adequate UV blocking.
  • 26% Water Content.
  • 360° Square edge design provides uninterrupted contact at the haptic-optic junction to limit LEE's migration.
  • Smooth lens surface reduces bacterial adhesion, inflammatory cell response and haptics for ease of unfolding.
  • Pre-vaulted design – continuous posterior surface contact with the capsular bag to prevent PCO.
  • The advanced IOL design – Stable and Perfect centration and ultimate stability in the capsular bag.
  • Optics are YAG Laser Compatible
  • Steam sterilization does away with the hazards of ETO residue.
Yes! I am interested

FLEXIOL AO

REQUEST CALLBACK

FLEXIOL AO
  • FLEXIOL AO
  • FLEXIOL AO
Ask for Price

Thanks for Contacting Us.

Product Price :Get Latest Price

Product Details:
Minimum Order Quantity100 Piece
TypeAspheric IOLs
MaterialHydrophilic Foldable Acrylate
Usage/ApplicationEye diseases/ Cataract Surgery
Lens TypeHydrophilic Acrylic Foldable Intraocular Lenses
Model Name/NumberFFA 6025,FFA 6025D
Estimated AC Depth4.96 mm
SterilizationSTEAM
PCO Protection360 Degree Step Square Edge on posterior Side
Available Powers+10.0 D to +35.0 D in 0.5 D steps,-5.0 D to +9.0 D & +31.0 to +35.0 D in 1.0 D Steps
Haptic design0 Degree Pre-vaulted
Optic SizeFFA 6025,FFA 6025D - 6.00 mm
Overall lengthFFA 6025,FFA 6025D - 12.50 mm
Optic DesignBiconvex-Aberration neutral Negative Aspheric Optic

Flexiol AO is an Aspheric acrylic Foldable IOL’s made of FDA approved Highly Bio-compatible ultra-pure monomer with low refractive index and blocking material.

Our Aspheric IOL’s designed with negative aberration neutral optics with 360o Advanced step square edge for superior optical performance and defence against PCO. Lower refractive index which minimizes problems with glare, external and internal reflections and other unwanted visual phenomena.

Our Aspheric IOL’s to be safely implanted in all patients whatever their corneal spherical aberrations.

Feature:

  • Aberration Neutral Aspheric optics-negative spherical aberration -0.27* wave front technology.
  • Excellent quality of vision and greatly increased contrast sensitivity. Peak visual performance in night vision and decreased glare.
  • Hydrophobic surface optics helps delayed PCO and well-polished haptic for ease of unfolding.
  • 360° Square edge design provides uninterrupted contact at the haptic-optic junction to limit LEE's migration.
  • Pre-vaulted haptic design-continuous posterior surface contact with the capsular bag to prevent PCO.
  • The advanced IOL design-Stable and Perfect centration and ultimate stability in the capsular bag.
  • Optics are YAG Laser Compatible.
  • ST Steam sterilization does away with the hazards of ETO residue.

 

Yes! I am interested

ASPROLENZ

REQUEST CALLBACK

ASPROLENZ
  • ASPROLENZ
  • ASPROLENZ
  • ASPROLENZ
  • +2 ASPROLENZ
Ask for Price

Thanks for Contacting Us.

Product Price :Get Latest Price

Product Details:
Minimum Order Quantity100 Piece
TypeAspheric IOLs
MaterialHydrophilic Foldable Acrylate
Usage/ApplicationEye Diseases/ Cataract Surgery
Optic DesignBiconvex-Aberration neutral Negative Aspheric Optic
Lens TypeHydrophilic Acrlyic Foldable Intraocular Lenses
Model Name/NumberFA 5725D,FA 6025,FA 6025D,FA 6030,FA 6010,FA 6005
Estimated AC Depth4.96 mm
Optic SizeFA 5725D - 5.75 mm,FA 6025,FA 6025D,FA 6030,FA 6010,FA 6005 - 6.00 mm
SterilizationSTEAM
Refractive Index1.46 @ 20 Degree C
Overall LengthFA 5725D,FA 6025,FA 6025D - 12.50 mm,FA 6030 - 13.00 mm,FA 6010 - 11.00 mm,FA 6005 - 10.50 mm
Pco Protection360 Degree Step Square Edge on posterior Side
Haptic Design0 Degree Pre-vaulted
Available Powers+10.0 D to +35.0 D in 0.5 D steps
Estimated A.constant118.0

Aspro lenz is an aspheric acrylic foldable IOL’s made of FDA approved highly bio-compatible ultra pure monomer with low refractive index and blocking material.

Our Aspheric IOL’s designed with negative aberration neutral optics with 360o Advanced step square edge for superior optical performance and defence against PCO. Lower refractive index which minimizes problems with glare, external and internal reflections and other unwanted visual phenomena.

Our Aspheric IOL’s to be safely implanted in all patients whatever their corneal spherical aberrations.

Features:

  • Aberration Neutral Aspheric optics –negative spherical aberration -0.18* wavefront technology.
  • Excellent quality of vision and greatly increased contrast sensitivity.
  • Hydrophobic surface optics helps delayed PCO and well polished haptics for ease of unfolding.
  • 360o Step square edge design provides uninterrupted contact at haptic-optic junction to limit LEC’s migration.
  • Pre-vaulted haptic design – continuous posterior surface contact with the capsular bag to prevent PCO.
  • The advanced IOL design – stable and perfect centration and ultimate stability in the capsular bag.
  • Optics is YAG laser compatible.
  • Steam sterilization does away with the hazards of ETO residue.
Yes! I am interested

View PDF

Flexiol

REQUEST CALLBACK

Flexiol
  • Flexiol
  • Flexiol
Ask for Price

Thanks for Contacting Us.

Product Price :Get Latest Price

Product Details:
Minimum Order Quantity100 Piece
MaterialHydrophilic Foldable Acrylate
Usage/ApplicationEye Diseases/ Cataract Surgery
Optic DesignBiconvex
Lens TypeHydrophilic Acrylic Foldable Intraocular Lenses
Optic Size6.00 mm
Overall Length12.50 mm
Pco Protection360 Degree Step Square Edge on posterior Side
Lens ModelFFS 6025,FFS 6025D
Haptic Design0 Degree Pre-vaulted
Available Powers+10.0 D to +30.0 D in 0.5 D steps,-5.0 D to +9.0 D & +31.0 to +35.0 D in 1.0 D Steps
SterilizationYes
Estimated A. constant118.0
Estimated AC. Depth4.96 mm

With enriched industrial experience and knowledge, we are providing our clients with a wide assortment of Flexiol Hydrophilic Acrylic Foldable IOLs. Designed with utmost precision, the offered lens is designed using quality-proven violet blue light filtering material with the aid of sophisticated technology in synchronization with set industry standards. In addition to this, the provided lens undergoes various tests by our quality controllers, in order to ensure its flawless nature.

Features:

  • Clear Hydrophilic
  • 26% Water Content
  • 360° Advanced Square edge


Other Details:

  • Ultra-Pure Hydrophilic Acrylic Material with adequate UV blocking.
  • 360° Square edge design provides uninterrupted contact at the haptic-optic junction to limit LEE's migration.
  • Smooth lens surface reduces bacterial adhesion, inflammatory cell response and haptics for ease of unfolding.
  • Pre-vaulted design – continuous posterior surface contact with the capsular bag to prevent PCO.
  • The advanced IOL design – Stable and Perfect centration and ultimate stability in the capsular bag.
  • Optics are YAG Laser Compatible
  • Steam sterilization does away with the hazards of ETO residue.

 

Yes! I am interested

ACCURAVUE

REQUEST CALLBACK

ACCURAVUE
  • ACCURAVUE
  • ACCURAVUE
  • ACCURAVUE
  • +2 ACCURAVUE
Ask for Price

Thanks for Contacting Us.

Product Price :Get Latest Price

Product Details:
Minimum Order Quantity100 Piece
TypeAspheric IOLs
MaterialHydrophilic Foldable Acrylate
Usage/ApplicationEye diseases/ Cataract Surgery
Optic DesignBiconvex
Lens TypeHydrophilic Acrylic Foldable Intraocular Lenses
Model Name/NumberYA 5725D,YA 6025,YA 6025D,YA 6030,YA 6010,YA 6005
Estimated AC Depth4.96 mm
SterilizationSTEAM
PCO Protection360 Degree Step Square Edge on posterior Side

Accura vue is yellow series acrylic foldable IOL’s made up of FDA approved highly bio-compatible ultra pure monomer with UV-A blocking and violet blue light filtering material which contains the same UV-A blocking and violet Blue light filtering chromophore that is in human crystalline lens.


Feature:

  • Aberration Neutral Aspheric optics-negative spherical aberration -0.27* wave front technology.
  • Excellent quality of vision and greatly increased contrast sensitivity. Peak visual performance in night vision and decreased glare.
  • Hydrophobic surface optics helps delayed PCO and well polished haptic for ease of unfolding.
  • 360° Square edge design provides uninterrupted contact at the haptic-optic junction to limit LEE's migration.
  • Pre-vaulted haptic design-continuous posterior surface contact with the capsular bag to prevent PCO.
  • The advanced IOL design-Stable and Perfect centration and ultimate stability in the capsular bag.
  • Optics are YAG Laser Compatible.
  • ST Steam sterilization does away with the hazards of ETO residue.
Yes! I am interested

 
X


Explore More Products

Contact via E-mail
Contact via SMS
Global Ophthalmic Private Limited
Kamban Selvaraj (Marketing Manager)
Plot No. 3, First Main Road, Sri Ramsamaji Nagar Extension, Vellanoor , Bharathi Nagar,
Chennai - 600062, Tamil Nadu, India
Call Us: 
Call Response Rate: 70%
Share Us :
F G T L



Home  |   Profile   |  Our Products  |  Site Map  |   Contact Us

© Global Ophthalmic Private Limited. All Rights Reserved (Terms of Use)
Developed and Managed by IndiaMART InterMESH Limited

Global Ophthalmic Private Limited